 PerFormanCe POWER PFC375
The PFC375 products of the PerFormanCe Power series incorporate high performance midrange power, active Power Factor Correction (PFC), and high reliability to meet varied commercial and industrial requirements. Providing tightly regulated DC power in a wide variety of single and multiple output configurations, the PFC375 is designed to provide full output power with only 300 Linear Feet per Minute FEATURES * Power Factor Correction (PFC) Meets EN61000-3-2 * Fully Regulated Outputs * Main Output Remote Sense * Current Share, Power Fail, and Power Good Signals * Overtemperature, Overvoltage, and Overcurrent Protected * Available with Metric and SAE Mountings * Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5 * Fan Output Voltage and Optional Fan SINGLE OUTPUT MODEL SELECTION CHART
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT (NOTE 1) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 2) INITIAL SETTING ACCURACY
(LFM) forced-air cooling (factory installed fan optional). Other features include remote sense, power fail, logic level inhibit, and DC power good. Main channel current sharing is provided for redundant applications. The PFC375 is available with SAE mountings or optional metric mountings. The PFC375 product line is approved to the latest international regulatory standards, and displays the CE Mark.
PFC375-1012 PFC375-1015 PFC375-1024 PFC375-1028 PFC375-1048
NOTES:
12V 15V 24V 28V 48V
10.8V to 13.5V 12.0V to 17.0V 21.6V to 26.4V 25.2V to 30.8V 46.0V to 56.0V
30A 25A 15A 13.4A 7.8A
0.2% 0.2% 0.5% 0.5% 0.5%
0.8% 0.6% 0.8% 0.9% 1.0%
1% 1% 1% 0.9% 1%
11.94V to 12.06V 14.94V to 15.06V 23.88V to 24.12V 27.86V to 28.14V 47.52V to 48.48V
1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
MULTIPLE OUTPUT MODEL SELECTION CHART - ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 2) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 3) INITIAL SETTING ACCURACY
PFC375-4000
PFC375-4001
PFC375-4002
PFC375-4004
+5V +12V 12V 5V +5V +12V 12V 12V +5V +12V 12V 24V +5V +12V 15V 15V
4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V Fixed 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 11.0V to 16.0V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 22.0V to 28.0V 4.5V to 5.5V 11.3V to 12.6V 14.2V to 15.8V 14.2V to 15.8V
3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 6A 3A 3.5 - 40A 10A 4A 4A
40A 16A 6A 3A 40A 16A 6A 3A 40A 16A 6A 3A 40A 16A 4A 4A
0.4% 0.9% 0.9% 2% 0.4% 0.9% 0.9% 0.9% 0.4% 0.9% 0.9% 0.5% 0.4% 0.9% 0.7% 0.7%
0.8% 0.9% 0.9% 2% 0.8% 0.9% 0.9% 0.9% 0.8% 0.9% 0.9% 0.8% 0.8% 0.9% 0.7% 0.7%
1% 1% 1% 2.4% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.9V to 5.1V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 11.9V to 12.1V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 14.9V to 15.1V 14.9V to 15.1V
REV. 07/01
1
PerFormanCe POWER PFC375
MULTIPLE OUTPUT MODEL SELECTION CHART (CONT.) - ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT (NOTE 1) PEAK OUTPUT CURRENT (NOTE 2) LINE REGULATION LOAD REGULATION RIPPLE & NOISE %p-p (NOTE 3) INITIAL SETTING ACCURACY
PFC375-4005 (Note 4)
PFC375-4200
PFC375-4201
+5V +12V 24V 24V +24V +5V 12V 12V +24V +5V 15V 15V +5V +12V 12V 5V
4.5V to 5.5V 11.3V to 12.6V 22.0V to 28.0V 22.0V to 28.0V 21.5V to 26.4V 4.5V to 5.5V 11.4V to 12.6V 11.4V to 12.6V 21.5V to 26.4V 4.5V to 5.5V 14.2V to 16.0V 13.7V to 16.0V 4.5V to 5.5V 11.3V to 12.6V 11.3V to 12.6V 4.5V to 5.5V
3.5 - 40A 10A 3A 3A 1 - 10A 10A 4A 4A 1 - 10A 10A 4A 4A 3.5 - 50A 10A 6A 3A
40A 16A 3A 3A 10A 16A 4A 4A 10A 16A 4A 4A 50A 16A 6A 3A
0.4% 0.9% 0.5% 0.5% 0.5% 0.4% 0.5% 0.5% 0.5% 0.4% 0.5% 0.5% 0.4% 0.9% 0.9% 2%
0.8% 0.9% 0.8% 0.8% 0.8% 0.8% 1% 1% 0.8% 0.8% 0.8% 0.8% 0.8% 0.9% 0.9% 0.9%
1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1%
4.98V to 5.02V 11.9V to 12.1V 23.8V to 24.2V 23.8V to 24.2V 23.8V to 24.2V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 23.8V to 24.2V 4.98V to 5.02V 14.9V to 15.1V 14.9V to 15.1V 4.98V to 5.02V 11.9V to 12.1V 11.9V to 12.1V 4.9V to 5.1V
PFC375-4500
NOTES: 1) 2) 3) 4)
Output currents ratings are expressed with 300 LFM forced air. Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts. Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. V3 and V4 may be series connected to obtain 48V.
INPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Input Frequency Brown Out Protection Hold-Up Time Input Current Input Protection Inrush Surge Current Power Factor Operating Frequency
Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 85 VAC at full rated load. Non-user serviceable internally located AC input line fuse, F10A, 250V. Internally limited by thermistor, one cycle, 25C. 110 VAC 220 VAC Per EN61000-3-2. Switching frequency of main transformer.
85 47 85 20
264 63
6 35 65 0.98 100
VAC Hz VAC mS ARMS APK W/VA kHz
OUTPUT SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Minimum Loads
Ripple and Noise Output Power
Overshoot / Undershoot Regulation Transient Response Turn-On Delay Turn-On Rise Time
Full rated load, 110 VAC. Varies with distribution of loads among outputs. Single output models. Multiple output models, 5V main output only. Multiple output models, 24V main output only. Full load, 20MHz bandwidth. 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. Peak power, all models. Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load. Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. (Main output only on multi-output units). Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%.
68 0 3.5 1 See Model Selection Charts 375 450 0 See Model Selection Charts 1 1 10
% Amps
Watts V
mS Sec mS
2
PerFormanCe POWER PFC375
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection
Overload Protection Overtemperature Protection Remote Sense Current Share Inhibit Input Power Fail Warning Power Good Fan Voltage
Provided on single output units and the main output only of multiple output units. PFC375-30XX, PFC375-40XX, PFC375-45XX 6.0 6.4 PFC375-1012 13.5 15.5 PFC375-1015 17.0 19.5 PFC375-1024 27.0 30.7 PFC375-1028 30.8 35.0 PFC375-1048 60.0 70.0 PFC375-42XX 27.0 30.7 Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. System shutdown due to excessive internal temperature, automatic reset. Total voltage compensation for cable losses with respect to the main output. 250 Accuracy of shared current with up to 6 parallel units. 10 TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. TTL compatible logic signal. Time before regulation dropout due to 5 loss of input power at 110 VAC. TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal. Provides 170 mA current to user-supplied fan, if fan option is not selected. 12
V
mV %
mS
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals
Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Insulation Resistance Leakage Current
UL1950. CSA 22.2 NO. 234/950. EN60950 (TUV). Input to output. FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. Per EN61000-4-2, level 4. Per EN61000-4-3, level 3. Per EN61000-4-4, level 4. Per EN61000-4-5 class 3. Input to output. Per EN60950, 264 VAC.
Approved 2600 B B 8 10 4 1 2 10 2.0 VDC Class kV V/M kV kV M mA
Line to Line Line to Ground
ENVIRONMENTAL SPECIFICATIONS
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Altitude Operating Temperature
Operating. Non-Operating. Derate linearly above 50C by 2.5% per C. At 100% load At 50% load 0 0 -55
Storage Temperature Forced Air Cooling
10k 40k 50 70 85
ASL Ft. ASL Ft. C C C
Temperature Coefficient Relative Humidity Shock Vibration
Forced air cooling of 300 LFM is required if the internal fan option is not specified. Cooling air velocity is measured 1/4" above, at the middle of the chassis. Airflow direction is from the input section to the output section. 0C to 70C (after 15-minute warmup). Non-Condensing. Operating: 103mS, 3 axis, Halfsine. Non-operating: 103mS, 3 axis, Halfsine. Operating: 5-32 Hz 32-2000 Hz Sinusoidal Non-operating:
0.02 5
0.05 95 20 40 0.02 1 6.15
%/C %RH G in (DA) GRMS GRMS
3
PerFormanCe POWER PFC375
OPTIONS
DESCRIPTION NOTES SIZE IMPACT
Fan Metric Mounting
Add "F" as a suffix to the model number to order integral fan. (provides required 300 LFM of forced air cooling). Add "M" as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts.
10.50" x 5.00" x 2.50" (266.7mm x 127.0mm x 63.5mm) 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm)
OVERALL SIZE: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm) OVERALL LENGTH WITH FAN: 10.50" (266.7mm) WEIGHT: 4.3 LBS (1.95 kg)
INPUT & OUTPUT CONNECTIONS: 6-32 SCREW TERMINAL ON 0.375" (9.5mm) CENTERS BUS BAR MAIN OUTPUT, E1 & E2, 10-32 SCREW TERMINAL CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH
4


▲Up To Search▲   

 
Price & Availability of PFC375-4004

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X